Manufactured to Form 2, Form 3 & Form 4 construction
Designed for both withdraw able & fixed versions
Ample cabling space for easy connections
Top and bottom cable entry.
Panels for front or rear access to suit application and site conditions
Ingress protection : IP 31 & IP 54
Floor mounting
Maximum safety & reliability
Full range of metering and instruments to meet customer requirements
Customized design to meet end user requirements.
Final Distribution Boards
Conforming with IEC 61439 1&2
Current rating up to 160A
Ingress protection : IP 41 & IP 54 as per IEC 61439-1&2
Available in Row type distribution, pan assembly (single or multi split arrangement) in flush or surface versions
Adopted range to local regulations, quality makes and easy installation
Synchronization Panel/Generator Control Panel
3-pole or 4-pole system as required
Various combinations of load transfer by ACBs, MCCB’s or Contactors
Protection class up to IP 54
Load sharing/load shedding
Automatic and manual synchronizing
Factory built to client's specifications
Ratings up to 4000A
Control functions available for engine monitoring, warm-up and cool down periods, emergency shutdown, multi attempt engine start control, engine test runs
Motor Control Center Panels
Conforming with IEC 61439-1 & 2
Rated up to 4000A
Manufactured to Form 2 & Form 4 construction
Designed for both withdraw able & fixed versions
Top and bottom cable entry.
Panels for front or rear access to suit application
Full range of instruments and metering to customers’ requirements
Tailored control using Contactor, DOL, Star Delta Starter, Soft starter and variable speed drives
Ingress protection : IP 31 & IP 54
BMS and PLC integration
Fire Alarm interfacing
Floor mounting
Maximum safety & reliability
Sub-Main Distribution Boards
Conforming to IEC 61439-1 & 2
Rated up to 1250A
Manufactured to Form 2 & Form 4 construction
Ample cabling space for easy connections
Ample cabling space for easy connections
Top and bottom cable entry.
Options for Isolator and MCCB Auto or Non-Auto incomers
Panels for front or rear access to suit application
Busbar and incomer terminals are fully shrouded as per DEWA regulations
Ingress protection : IP 31 & IP 54
Floor or wall mounted with surface and flush mounting options
Finish as per RAL 7032. Other finishes on request.
Provision to add on Metering Kits and extension cable boxes.
Option to build to customers special requirements
Compact designs
Capacitor banks
Conforming to IEC 61439 – 1 & 2, IEC 61921
Rated up to 600KVAR Bank
Segregation Form 2
Ingress protection up to IP54
Wall mounting or floor standing
With or without Harmonic Filters
Top or bottom cable entry
ATS (Automatic Transfer Switch) Panels
Conforming to IEC 61439 - 1 & 2
Segregation up to Form 2 (Other Form type for higher rating on request)
Sheet steel and GRP Enclosures
Ingress protection IP41 (Up to IP66 on request)
Wall mounting or floor standing
Top, bottom or special cable entry
Front/ Rear cabling access
Interlocks are ensured in electrical as well as mechanical.
Special control systems to customers requirements
Motorized ACB/ MCCB type Contactors
Microprocessor based Automatic Controller type ATS